New Spectra 1759EX Wireless and Hardwired System

The Spectra 1759EX is a 15-zone wireless and hardwired system with a built-in 433MHz Omnia wireless receiver. In addition to the 5 on-board hardwired zones and 2 keypad zones, the 1759EX supports 8 wireless transmitters and 8 remote controls—all without any extra modules. The 1759EX supports the Omnia line of wireless transmitters, including motion detectors, door contacts and remote controls.

6- to 16-Zone Expandable Bus Systems

Spectra offers a winning combination of unique features and an advanced communication bus for a reliable and expandable security system. Through its communication bus, Spectra can be expanded to 16 fully programmable zones via wireless and/or hardwire zone expansion bus modules and a variety of accessory bus modules. If you're looking for the best in its class, look to Spectra!

Main Features
  • Expandable to 16 zones
  • 4-wire communication bus
  • 2 independent partitions
  • 48 user codes
  • 1.5A switching power supply
  • 256 event buffer
  • False alarm prevention package with Intellizone
  • Module, phone line, bell/siren and tamper supervision
  • Fuseless technology reduces service calls

1759EX
7 to 15 Zones
  • 8 wireless zones and 8 remote controls
  • 5 on-board hardwired zones
  • 2 keypad zones
  • Supports all Omnia transmitters
  • 2 PGM outputs
  • 5A alarm relay
  • CE and UL approval currently in process

1727
6-Zone 'Local' System
  • 4 on-board zones + 1 keypad zone + 1 dedicated fire zone
  • 8 user codes
  • 2 PGM outputs
  • Includes 1686H or 1686V LED keypad
  • No dialer
  • Metal box: 8' x 10' x 3' (20cm x 25cm x 8cm

1728EX/1728
7 to 16 Zones
  • 1728EX: 5 zones + 2 keypad zones (1 per keypad)
  • 1728: 10 zones (5 inputs x 2 w/ATZ) + 2 keypad zones (1 per keypad)
  • Expandable to 16 zones using hardwire and/or wireless expansion bus modules
  • Supports Auto-Panel Recognition Modules (APR3)
  • 1 PGM output (150mA)
  • Metal box: 8' x 10' x 3' (20cm x 25cm x 8 cm)
1738EX/1738
9 to 16 Zones
  • 1738EX: 7 zones + 2 keypad zones (1 per keypad)
  • 1738: 14 zones (7 inputs x 2 w/ATZ) + 2 keypad zones (1 per keypad)
  • Expandable to 16 zones using hardwire and/or wireless expansion bus modules
  • Supports Auto-Panel Recognition modules (APR3)
  • 2 PGM outputs (2.5A) + 1 optional 5A relay output
  • Metal box: 8' x 10' x 3' (20cm x 25cm x 8 cm)
Zone Expansion Bus Modules

Need to add wireless or hardwired zones? Simply connect the desired expansion bus modules anywhere on Spectra's 4-wire communication bus without having to homerun wires back to the control panel.

SPC-ZX4
4-Zone Expansion Bus Module
  • Adds 4 fully programmable hardwire zones

SPC-ZX8
8-Zone Expansion Bus Module
  • Adds 8 fully programmable hardwire zones
  • 1 PGM output (50mA)

SPC-319
900MHz Wireless Bus Module
  • Adds 8 fully supervised wireless zones
  • Adds 8 programmable remote controls
  • 900MHz Spread Spectrum Technology
  • Compatible with all Liberator™ transmitters
  • 1 programmable 5A relay output (+1 optional)
Bus Keypads

Spectra's range of elegant keypads enhance any décor. With their large backlit buttons, clear status lights and one-touch functions, Spectra keypads are beautifully simple to use.

Spectra Keypad Main Features
  • Compatible with the entire line of Spectra control panels
  • Connect anywhere on the 4-wire communication bus
  • 1 on-board hardwire zone input
  • Key-selected chime zones (per keypad/per zone)
  • One-touch action buttons
  • 3 keypad-activated panic alarms
  • Adjustable keypad backlight

1686H
10-Zone LED Keypad
  • Separate arm LED per partition
  • Patented 'key light' display † (button lights up to indicate an open zone)
  • No jumpers. Set keypad zone, tamper and EOL via keypad programming

1686V
10-Zone LED Keypad
  • Separate arm LED per partition
  • Patented 'key light' display † (button lights up to indicate an open zone)
  • No jumpers. Set keypad zone, tamper and EOL via keypad programmin
1689
16-Zone LED Keypad
  • Separate arm and stay LEDs per partition
  • Separate LEDs for zone displa

1641
LCD Keypad
  • 32-character LCD screen
  • Programmable messages
  • Adjustable backlight display, contrast and scroll speed
  • 1 PGM output (50mA)
WE SHIP NATIONWIDE
We Accept Purchase Orders
In addition to all the major credit cards we accept purchase orders from Fortune 1000 corporations, educational institutions, and government agencies.
All purchase order terms are Net 30 days. Please fax your purchase order to (718) 259-3294
Paradox Spectra 1728 Ex User Manual

Paradox Spectra 1728 Ex User Manual Pdf

SEARCH BY BRAND|SHOPPING LIST |CONTACT US|ABOUT US|HOME

Paradox Spectra 1728ex User Manual

Paradox sp5500 installation manual offer PARADOX 1738 USER MANUAL PARADOX SPECTRA ALARM MANUAL. Paradox Spectra 1738 User Guidesaxonville Mills apr 11, 2015 - the person paradox spectra 1738 user guide could have more than one name. Some refer to it. System Programming Guide 1728: V2.4 1738: V2.4 Default Installer Code 0000 / 000000 (see. The Spectra 1727 control panel includes two programmable outputs (PGMs) that provide a maximum of 50mA each. When a specific event occurs in the system, a PGM can reset smoke detectors, activate strobe lights, open/ close garage doors and much more. Connect the PGMs according toFigure 8-3: PGM Connectionson page 19. Paradox Spectra 1728EX Programming/Reference Manual - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Paradox Spectra ion 1728, 1738.

Paradox Spectra 1728 Ex User Manual Software

© Privacy Policy